Conduit Connection PTY LTD

All Types of Conduits and Accessories

screen-shot-2022-11-16-at-1-50-42-pm

Latest News

Flammability Test as per correct testing procedure in a recognized laboratory with conduit mounted vertically and the flame at a 45 degree angle as stipulated by AS/NZS 61386.

It has been brought to our attention that there are fake videos in circulation that are showing an incorrect testing procedure. These videos have also been doctored to portray Dietzel
Univolt’s HFT conduit in an extremely negative manner. Dietzel Univolt take great pride in being the inventor and world leader in LSFOH (HFT) cable management technology.
Dietzel Univolt are regularly audited to ensure all manufacturing processes are strictly adhered to. You can have confidence that the Dietzel Univolt HFT conduit supplied to you will meet all the applicable standards.
Dietzel Univolt recommends and welcomes meticulous scrutiny of all test reports, as any test reports that have been altered or tampered with in any way are invalid.

Dietzel Univolt - Your quality partner

The brand name Univolt is today internationally recognized as a synonym for a vivid, innovative spirit and culture, first class product quality and service at the highest stage. The focus of our efforts is to increase the benefit for our customers.
Our priorities are controlled and sustainable growth and to maintain our leading position in selected sales markets – by deliberate investments, elaborated innovations and further improvement of our high-quality products.
New Transport NSW Standard Code

TfNSW New Standard TS 04955.8

Transport for NSW have released a new standard for low voltage electrical installations effective from 09/01/2025.
Clause 8.1 brings the requirements for LSZH conduit in line with International and Australian Standards.
For any LSZH conduit installed, it must comply with AS/NZS 61386, AS/NZS 61034, AS/NZS 60754, IEC63355.
The Dietzel Univolt HFT conduit we supply meets this criteria.

Is it LSFOH, LSZH, LSOH, LSFH, OHLS or ZHFR?

Are you sure?

Check to be sure what you get. Not all manufacturers meet international standards and safety requirements when labelling their products.

Low Smoke (LS)

Smoke caused by burning plastics poses a massive threat to human lives. PVC conduits can never comply with low smoke requirements due to material properties. Only IEC 61034 compliant conduits can be considered "low smoke."

Flame Retardancy (F) 

To avoid flame propagation, conduits have to be flame retardant. Halogen-free conduits need specific additives, PVC is genuinely flame retardant. Conduits that comply with IEC 61386 can be labelled "flame retardant."

Zero Halogen (OH)

Halogens are dangerous because they create aggressive gases and fumes in case of fire, even if released in small quantities. PVC contains chlorine and therefore is not halogen-free. Halogen-free plastics have to comply with IEC 60754.